What's the matter with the dripping water from the outdoor unit of the air conditioner? No wonder you use it like this!

What's the matter with the dripping water from the outdoor unit of the air conditioner? No wonder you use it like this!

The sun is shining outside, but my friend downstairs said it rained. I said he was joking. How is it possible? He said if you don't believe it, come and have a look. It turned out that the outdoor unit of my air conditioner was dripping. I was so ashamed that I quickly checked the causes of dripping and how to solve it# Air conditioning#

Causes and solutions of dripping water from outdoor unit of air conditioner

1. After long-term use of the air conditioner and the poor quality of the drainage pipe of the air conditioner, the aging, bending, damage and other faults of the drainage pipe will lead to dripping during the operation of the outdoor unit of the air conditioner. For this reason, it is recommended to replace the drainage pipe with a new one with good quality.

2. Check whether the drainage pipe of the air conditioner is blocked by something. Due to the blockage of foreign matters in the drainage reputation, the water droplets inside the air conditioner can not be discharged, resulting in the dripping phenomenon of the outdoor unit of the air conditioner. In this case, check the specific problems of the drainage pipe, and then take out the foreign matters, and then check whether the connection between the drainage pipe and the air conditioner pipe is normal.

3. If the air conditioner is not installed in place, it will also cause water dripping of the outdoor unit of the air conditioner. Because the installation is not firm, the position on one side of the drainage pipe will shift for a long time, resulting in water dripping. The solution to this situation is to move the air conditioner, lower one end of the drain of the air conditioner condensate pipe, and use professional instruments to correct the air conditioner to a horizontal position.

4. Due to the poor quality of materials on the pipeline or poor installation, the refrigerant in the pipeline will cause condensation and water dripping when passing through. It is recommended to check whether the thermal insulation materials are aging or poorly installed. In this case, it is recommended to replace the aging adhesive tape of the pipeline to maintain the tightness of the copper pipe.

The above are the reasons for the dripping of the outdoor unit of the air conditioner and the solutions. I hope it will be helpful to you.